|  | Motor Connecting Cables |  | |
|  | |||
| 2YSLCY-JB/2YSLCYK-JB |  |  | 9YSLCY-JB |  | PENDANT CABLE |  | 
 Mineral insulated cables
Mineral insulated cables
      Mineral Insulated Heating Cable,single core up to 700 °C
Application
Moisture proof applications at high outputs and temperatures
High-temperature sistuations
Can be immersed in fluids
Chemical & petrochemical industries
Machinery and plant construction
Molten Salt Applications
Vacuum technology
Heat tracing on piping
Heat tracing on vessels
Voltage Rating
500V
CABLE CONSTRUCTION

Conductors: Solid alloy or copper conductor.
Insulation: Magnesium Oxide (MgO).
Outer sheath: Stainless Steel 1.4541 (AISI 321).
Mechanical and Thermal Properties
Maximum Operating temperature: 700℃
Maximum continuous exposure temperature: 600℃
Minimum installation temperature: -60℃
Bending radius: 5×OD
Nominal output: 250 W/m
Cold lead, length: 2 x 0.50 m
Cable Parameter
| Overall Diameter mm | Resistance at 20 °C | Temperature coefficient | 
|---|---|---|
| 3.20 | 10000 | 0.09 | 
| 3.20 | 6300 | 0.09 | 
| 3.20 | 4000 | 0.09 | 
| 3.40 | 2500 | 0.09 | 
| 3.60 | 1600 | 0.09 | 
| 3.90 | 1000 | 0.09 | 
| 4.30 | 630 | 0.09 | 
| 4.70 | 400 | 0.09 | 
| 5.30 | 250 | 0.09 | 
| 6.50 | 160 | 0.09 | 